First Alert Battery Operated Smoke Alarm With Escape Light User Manual

Browse online or download User Manual for Smoke detectors First Alert Battery Operated Smoke Alarm With Escape Light. First Alert Battery Operated Smoke Alarm With Escape Light User's Manual

  • Download
  • Add to my manuals
  • Print
  • Page
    / 2
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 0
IMPORTANT!
PLEASE READ CAREFULLY AND SAVE.
This user’s manual contains important
information about your Smoke Alarm’s operation.
If you are installing this Smoke Alarm for use by
others, you must leave this manual—
or a copy of it—with the end user.
USER’S MANUAL
M
08-0069-009 J1 02/12 Printed in Mexico
L
ISTED TO
UL 217
STANDARD
Model SA304
SMOKE ALARM WITH SILENCE AND
E
SCAPE LIGHT
®
F
EATURES
TABLE OF CONTENTS
Fire Safety Tips . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1
B
efore You Install This Smoke Alarm . . . . . . . . . . . . . . . . . . . . . . . . .1
How To Install This Smoke Alarm . . . . . . . . . . . . . . . . . . . . . . . . . .2-3
O
ptional Locking Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2-3
W
eekly Testing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2
R
egular Maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2-3
I
f This Smoke Alarm Sounds . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3
What To Do In Case Of Fire . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3
U
sing the Silence Feature . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4
If You Suspect A Problem . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4
L
imited Warranty . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4
Recommended Locations For Smoke Alarms . . . . . . . . . . . . . . . .4-5
L
ocations To Avoid For Smoke Alarms . . . . . . . . . . . . . . . . . . . . . . .5
A
bout Smoke Alarms . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5
Special Compliance Considerations . . . . . . . . . . . . . . . . . . . . . . . . .6
L
imitations Of Smoke Alarms . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6
© 2012 BRK Brands, Inc. All rights reserved. Distributed by BRK Brands, Inc.
3
901 Liberty Street Road, Aurora, IL 60504-8122
C
onsumer Affairs: (800) 323-9005 www.firstalert.com
FIRE SAFETY TIPS
F
ollow safety rules and prevent hazardous situations: 1) Use smoking
m
aterials properly. Never smoke in bed. 2) Keep matches or lighters
a
way from children; 3) Store flammable materials in proper containers;
4
) Keep electrical appliances in good condition and don’t overload elec-
t
rical circuits; 5) Keep stoves, barbecue grills, fireplaces and chimneys
g
rease- and debris-free; 6) Never leave anything cooking on the stove
u
nattended; 7) Keep portable heaters and open flames, like candles,
a
way from flammable materials; 8) Don’t let rubbish accumulate.
K
eep alarms clean, and test them weekly. Replace alarms immediately if
t
hey are not working properly. Smoke Alarms that do not work cannot alert
you to a fire. Keep at least one working fire extinguisher on every floor, and
an additional one in the kitchen. Have fire escape ladders or other reliable
means of escape from an upper floor in case stairs are blocked.
BEFORE YOU INSTALL THIS SMOKE ALARM
IMPORTANT! Read “Recommended Locations for Smoke Alarms”
and “Locations to Avoid for Smoke Alarms” before beginning. This
unit monitors the air, and when smoke reaches its sensing chamber, it
alarms. It can give you more time to escape before fire spreads. This
unit can ONLY give an early warning of developing fires if it is installed,
maintained and located where smoke can reach it, and where all resi-
dents can hear it, as described in this manual. This unit will not sense
gas, heat, or flame. It cannot prevent or extinguish fires.
Understand The Different Type of Smoke Alarms
Battery powered or electrical? Different Smoke Alarms provide
different types of protection. See “About Smoke Alarms” for details.
Know Where To Install Your Smoke Alarms
Fire Safety Professionals recommend at least one Smoke Alarm on
every level of your home, in every bedroom, and in every bedroom
hallway or separate sleeping area. See “Recommended Locations For
Smoke Alarms” and “Locations To Avoid For Smoke Alarms” for details.
Know What Smoke Alarms Can and Can’t Do
A Smoke Alarm can help alert you to fire, giving you precious time to
escape. It can only sound an alarm once smoke reaches the sensor.
See “Limitations of Smoke Alarms” for details.
Check Your Local Building Codes
This Smoke Alarm is designed to be used in a typical single-family
home. It alone will not meet requirements for boarding houses,
apartment buildings, hotels or motels. See “Special Compliance
Considerations” for details.
WEEKLY TESTING
NEVER use an open flame of any kind to test this unit. You might
accidentally damage or set fire to the unit or to your home. The
built-in test switch accurately tests the unit’s operation as required
by Underwriters Laboratories, Inc. (UL).
It is important to test this unit every week to make sure it is working
properly. Using the Test/Silence button is the recommended way to test
this Smoke Alarm. Press and hold the Test/Silence button on the cover of
the unit until the alarm sounds and the Escape Light
®
turns on (the unit
may continue to alarm for a few seconds after you release the button).
If it does not alarm, make sure the unit is receiving power and test it
again. If it still does not alarm, replace it immediately. During testing you
will hear a loud, repeating horn pattern: 3 beeps, pause, 3 beeps, pause.
The Escape Light
®
will turn on. LED flashes once every second.
H
OW TO INSTALL THIS SMOKE ALARM
THE PARTS OF THIS SMOKE ALARM
FOLLOW THESE SIMPLE STEPS!
Tools you will need:
Pencil • Drill with 3/16” (5 mm) drill bit
Hammer • Standard Flathead screwdriver
1
. Remove the mounting bracket from the Smoke Alarm base. Hold
t
he mounting bracket against the ceiling (or wall) and make a mark
a
t the center of each of the mounting slots with a pencil.
2
. Put the unit where it won’t get covered with dust when you drill
t
he mounting holes.
3
. Using a 3/16” (5 mm) drill bit, drill a hole through each pencil mark.
4
. Insert the plastic screw anchors (in the plastic bag with screws)
i
nto the holes. Tap the screw anchors gently with a hammer, if
n
ecessary, until they are flush with the ceiling or wall.
5. Tighten the screws (provided) into the screw anchors.
All First Alert
®
Smoke Alarms conform to regulatory requirements,
including UL217 and are designed to detect particles of combustion.
Smoke particles of varying number and size are produced in all fires.
I
onization technology is generally more sensitive than photoelectric
t
echnology at detecting small particles, which tend to be produced
i
n greater amounts by flaming fires, which consume combustible
m
aterials rapidly and spread quickly. Sources of these fires may include
p
aper burning in a wastebasket, or a grease fire in the kitchen.
Photoelectric technology is generally more sensitive than ionization
technology at detecting large particles, which tend to be produced
in greater amounts by smoldering fires, which may smolder for
hours before bursting into flame. Sources of these fires may include
cigarettes burning in couches or bedding.
F
or maximum protection, use both types of Smoke Alarms on each
l
evel and in every bedroom of your home.
This unit will not alert hearing impaired residents. It is recom-
mended that you install special units which use devices like
flashing strobe lights to alert the hearing impaired.
Do not connect this unit to any other alarm or auxiliary
device. It is a single-station unit that cannot be linked to
other devices. Connecting anything else to this unit may
prevent it from working properly.
Unit will not operate without battery power. The Smoke
Alarm cannot work until you install the battery in the correct
position (Match “+” to “+” and “-” to “-”).
This Smoke Alarm has a battery drawer which resists closing
unless a battery is installed. This warns you the unit will not
operate without a battery.
Do not install this unit over an electrical junction box.
Air currents around junction boxes can prevent smoke from
reaching the sensing chamber and prevent the unit from
alarming. Only AC powered units are intended for installation
over junction boxes.
Do not stand too close to the unit when the alarm is sounding.
It is loud to wake you in an emergency. Exposure to the horn
at close range may harm your hearing.
Do not paint over the unit. Paint may clog the openings to the
sensing chamber and prevent the unit from operating properly.
1 2 3
6
. Activate the battery. With the battery
c
ompartment open, install the battery
s
o the terminals on the battery match
t
he terminals on the Smoke Alarm.
M
atch “+” to “+” and “-” to “-.” Push
t
he battery in until it snaps in securely
a
nd cannot be shaken loose.
I
f the battery is not snapped in completely, the unit cannot receive
b
attery power. The Smoke Alarm may beep briefly when you install
t
he battery—this is normal.
7.
Position the base of the Smoke Alarm over the mounting bracket
and turn. The Alarm can be positioned over the bracket every 60°.
Turn the Smoke Alarm clockwise (right) until the unit is in place.
8. Test the Smoke Alarm. See “Weekly Testing.”
REGULAR MAINTENANCE
This unit has been designed to be as maintenance free as possible, but
there are a few simple things you must do to keep it working properly.
Use only the replacement batteries listed below. The unit may not
operate properly with other batteries. Never use rechargeable
batteries since they may not provide a constant charge.
Test it at least once a week.
Clean the Smoke Alarm at least once a month; gently vacuum the
outside of the Smoke Alarm using your household vacuum’s soft
brush attachment. A can of clean compressed air (sold at computer
or office supply stores) may also be used. Follow manufacturer
instructions for use. Test the Smoke Alarm. Never use water,
cleaners or solvents since they may damage the unit.
If the Smoke Alarm becomes contaminated by excessive dirt, dust
and/or grime, and cannot be cleaned to avoid unwanted alarms,
replace the unit immediately.
Relocate the unit if it sounds frequent unwanted alarms. See
“Locations to Avoid for Smoke Alarms” for details.
When the battery becomes weak, the Smoke Alarm unit will “chirp”
about once a minute (the low battery warning). This low battery
warning should last for 30 days, but you should replace the battery
immediately to continue your protection.
Choosing a replacement battery:
Your Smoke Alarm requires one standard 9V battery. The following
batteries are acceptable as replacements: Duracell #MN1604, (Ultra)
#MX1604, U9VL-J-P. These batteries are available at many local
retail stores.
Continued...
The Parts of This Unit
1. Mounting Bracket
2. Mounting Slots and Screws
3
. Locking Pins (break out of bracket)
4. Latch to Open Battery Compartment
5. Swing-Out Battery Compartment
To remove the mounting bracket
from the Smoke Alarm base, hold the
Smoke Alarm base firmly and twist the
mounting bracket counterclockwise.
1
2
3
2
5
4
3
LIMITED WARRANTY
B
RK Brands, Inc., ("BRK") the maker of First Alert
®
b
rand products
w
arrants that for a period of ten years from the date of purchase, this
p
roduct will be free from defects in material and workmanship. BRK, at
i
ts option, will repair or replace this product or any component of the
p
roduct found to be defective during the warranty period. Replacement
w
ill be made with a new or remanufactured product or component. If the
p
roduct is no longer available, replacement may be made with a similar
p
roduct of equal or greater value. This is your exclusive warranty.
This warranty is valid for the original retail purchaser from the date of
initial retail purchase and is not transferable. Keep the original sales
receipt. Proof of purchase is required to obtain warranty performance.
BRK dealers, service centers, or retail stores selling BRK products do
not have the right to alter, modify or any way change the terms and
conditions of this warranty.
T
his warranty does not cover normal wear of parts or damage resulting
f
rom any of the following: negligent use or misuse of the product, use on
i
mproper voltage or current, use contrary to the operating instructions,
d
isassembly, repair or alteration by anyone other than BRK or an author-
i
zed service center. Further, the warranty does not cover Acts of God,
s
uch as fire, flood, hurricanes and tornadoes or any batteries that are
i
ncluded with this unit.
B
RK shall not be liable for any incidental or consequential damages
c
aused by the breach of any express or implied warranty. Except to
t
he extent prohibited by applicable law, any implied warranty of
m
erchantability or fitness for a particular purpose is limited in duration
t
o the duration of the above warranty. Some states, provinces or
j
urisdictions do not allow the exclusion or limitation of incidental or
c
onsequential damages or limitations on how long an implied warranty
l
asts, so the above limitations or exclusion may not apply to you. This
w
arranty gives you specific legal rights, and you may also have other
r
ights that vary from state to state or province to province.
H
ow to Obtain Warranty Service
S
ervice: If service is required, do not return the product to your retailer.
I
n order to obtain warranty service, contact the Consumer Affairs Division
a
t 1-800-323-9005, 7:30 AM - 5:00 PM Central Standard Time, Monday
t
hrough Friday. To assist us in serving you, please have the model
n
umber and date of purchase available when calling.
F
or Warranty Service return to:
B
RK Brands, Inc., 25 Spur Drive, El Paso, TX 79906
Battery: BRK Brands, Inc. make no warranty, express or implied, written
or oral, including that of merchantability or fitness for any particular
purpose with respect to battery.
I
F YOU SUSPECT A PROBLEM
Smoke Alarms may not operate properly because of dead, missing or
weak batteries, a build-up of dirt, dust or grease on the Smoke Alarm
cover, or installation in an improper location. Clean the Smoke Alarm as
described in “Regular Maintenance,” and install a fresh battery, then test
the Smoke Alarm again. If it fails to test properly when you use the test
button, or if the problem persists, replace the Smoke Alarm immediately.
If you hear a “chirp” once a minute, replace the battery.
If you experience frequent non-emergency alarms (like those
c
aused by cooking smoke), try relocating the Smoke Alarm.
If the alarm sounds when no smoke is visible, try cleaning or
r
elocating the Smoke Alarm. The cover may be dirty.
If the alarm does not sound during testing, try installing a new
b
attery, and make sure it is snapped in securely.
If the Escape Light
®
d
oes not light during testing, make sure
t
he bulb is working properly. If you suspect the bulb is burned
o
ut, it is not replaceable.
If the Smoke Alarm is still not operating properly, and it is still under
warranty, please see “How to Obtain Warranty Service” in the Limited
Warranty below.
Do not try fixing the alarm yourself – this will void your warranty!
RECOMMENDED LOCATIONS FOR SMOKE ALARMS
Installing Smoke Alarms in Single-Family Residences
The National Fire Protection Association (NFPA), recommends one
Smoke Alarm on every floor, in every sleeping area, and in every bed-
room. In new construction, the Smoke Alarms must be AC powered and
interconnected. See “Agency Placement Recommendations” for details.
For additional coverage, it is recommended that you install a Smoke
Alarm in all rooms, halls, storage areas, finished attics, and basements,
where temperatures normally remain between 40˚ F (4.4˚ C) and 100˚ F
(37.8˚ C). Make sure no door or other obstruction could keep smoke
from reaching the Smoke Alarms.
More specifically, install Smoke Alarms:
On every level of your home, including finished attics and basements.
Inside every bedroom, especially if people sleep with doors closed.
In the hall near every sleeping area. If your home has multiple
sleeping areas, install a unit in each. If a hall is over 40 feet (12
meters)
long, install an alarm at each end.
At the top of the first-to-second floor stairway, and at bottom of
basement stairway.
Specific requirements for Smoke Alarm installation vary from state to
state and from region to region. Check with your local Fire Department
for current requirements in your area. It is recommended AC or AC/DC
units be interconnected for added protection.
AGENCY PLACEMENT RECOMMENDATIONS
N
FPA 72 Chapter 29
“For your information, the National Fire Alarm and Signaling Code,
NFPA 72, reads as follows:”
29.5.1* Required Detection.
2
9.5.1.1* Where required by other governing laws, codes, or standards
f
or a specific type of occupancy, approved single and multiple-station
s
moke alarms shall be installed as follows:
(1)*In all sleeping rooms and guest rooms
(2)*Outside of each separate dwelling unit sleeping area, within 21 ft
(6.4 m) of any door to a sleeping room, with the distance measured
along a path of travel
(
3) On every level of a dwelling unit, including basements
(4) On every level of a residential board and care occupancy (small
facility), including basements and excluding crawl spaces and
unfinished attics
(
5)*In the living area(s) of a guest suite
(6) In the living area(s) of a residential board and care occupancy
(small facility)
(
Reprinted with permission from NFPA 72
®
,
National Fire Alarm and
S
ignaling Code Copyright © 2010 National Fire Protection Association,
Q
uincy, MA 02269. This reprinted material is not the complete and
o
fficial position of the National Fire Protection Association, on the
r
eferenced subject which is represented only by the standard in its
e
ntirety), (National Fire Alarm and Signaling Code
®
a
nd NFPA 72
®
a
re
r
egistered trademarks of the National Fire Protection Association, Inc.,
Q
uincy, MA 02269).
C
alifornia State Fire Marshal (CSFM)
E
arly warning detection is best achieved by the installation of fire
d
etection equipment in all rooms and areas of the household as follows:
A
Smoke Alarm installed in each separate sleeping area (in the vicinity,
b
ut outside bedrooms), and Heat or Smoke Alarms in the living rooms,
d
ining rooms, bedrooms, kitchens, hallways, finished attics, furnace
r
ooms, closets, utility and storage rooms, basements, and attached
g
arages.
L
OCATIONS TO AVOID FOR SMOKE ALARMS
F
or best performance, it is recommended you AVOID installing
S
moke Alarms in these areas:
Where combustion particles are produced. Combustion particles
f
orm when something burns. Areas to avoid include poorly ventilated
k
itchens, garages, and furnace rooms. Keep units at least 20 feet
(
6 meters) from the sources of combustion particles (stove, furnace,
w
ater heater, space heater) if possible. In areas where a 20-foot
(
6 meter) distance is not possible – in modular, mobile, or smaller
h
omes, for example – it is recommended the Smoke Alarm be
p
laced as far from these fuel-burning sources as possible. The
p
lacement recommendations are intended to keep these Alarms at
a
reasonable distance from a fuel-burning source, and thus reduce
unwanted” alarms. Unwanted alarms can occur if a Smoke Alarm
i
s placed directly next to a fuel-burning source. Ventilate these
a
reas as much as possible.
In air streams near kitchens. Air currents can draw cooking smoke
into the sensing chamber of a Smoke Alarm near the kitchen.
In very damp, humid or steamy areas, or directly near bathrooms
w
ith showers. Keep units at least 10 feet (3 meters) away from
s
howers, saunas, dishwashers, etc.
Where the temperatures are regularly below 40˚ F (4.4˚ C) or above
100˚ F (37.8˚ C), including unheated buildings, outdoor rooms,
porches, or unfinished attics or basements.
In very dusty, dirty, or greasy areas. Do not install a Smoke Alarm
d
irectly over the stove or range. Keep laundry room Smoke Alarms
f
ree of dust or lint.
Near fresh air vents, ceiling fans, or in very drafty areas. Drafts can
blow smoke away from the unit, preventing it from reaching the
sensing chamber.
In insect infested areas. Insects can clog openings to the sensing
chamber and cause unwanted alarms.
Less than 12 inches (305mm) away from fluorescent lights.
E
lectrical “noise” can interfere with the sensor.
In “dead air” spaces. “Dead air” spaces may prevent smoke from
reaching the Smoke Alarm.
Avoiding Dead Air Spaces
“Dead air” spaces may prevent smoke from reaching the Smoke Alarm.
To avoid dead air spaces, follow the installation recommendations below.
On ceilings, install Smoke Alarms as close to the center of the ceiling
as possible. If this is not possible, install the Smoke Alarm at least
4 inches (102 mm) from the wall or corner.
For wall mounting (if allowed by building codes), the top edge of
Smoke Alarms should be placed between 4 and 12 inches (102 and
305 mm) from the wall/ceiling line, below typical “dead air” spaces.
On a peaked, gabled, or cathedral ceiling, install the first Smoke
Alarm within 3 feet (0.9 meters) of the peak of the ceiling, measured
horizontally. Additional Smoke Alarms may be required depending on
the length, angle, etc. of the ceiling's slope. Refer to NFPA 72 for
details on requirements for sloped or peaked ceilings.
SPECIAL COMPLIANCE CONSIDERATIONS
This Smoke Alarm is suitable for use in apartments, condominiums,
townhouses, hospitals, day care facilities, health care facilities, boarding
houses, group homes and dormitories provided a primary fire detection
system already exists to meet fire detection requirements in common
areas like lobbies, hallways, or porches. Using this Smoke Alarm in
common areas may not provide sufficient warning to all residents or
meet local fire protection ordinances/regulations.
T
his Smoke Alarm alone is not a suitable substitute for complete fire
d
etection systems in places housing many people—like apartment
b
uildings, condominiums, hotels, motels, dormitories, hospitals, health
c
are facilities, nursing homes, day care facilities, or group homes of any
k
ind. It is not a suitable substitute for complete fire detection systems
i
n warehouses, industrial facilities, commercial buildings, and special-
p
urpose non-residential buildings which require special fire detection
a
nd alarm systems. Depending on the building codes in your area, this
S
moke Alarm may be used to provide additional protection in these
f
acilities.
In new construction, most building codes require the use of AC or
AC/DC powered Smoke Alarms only. In existing construction, AC,
AC/DC, or DC powered Smoke Alarms can be used as specified by
local building codes. Refer to NFPA 72 (National Fire Alarm and
Signaling Code) and NFPA 101 (Life Safety Code), local building codes,
or consult your Fire Department for detailed fire protection requirements
in buildings not defined as “households”.
LIMITATIONS OF SMOKE ALARMS
Smoke Alarms have played a key role in reducing deaths resulting from
home fires worldwide. However, like any warning device, Smoke Alarms
can only work if they are properly located, installed, and maintained, and
if smoke reaches them. They are not foolproof.
S
moke alarms may not waken all individuals. Practice the escape
p
lan at least twice a year, making sure that everyone is involved – from
k
ids to grandparents. Allow children to master fire escape planning and
p
ractice before holding a fire drill at night when they are sleeping.
I
f children or others do not readily waken to the sound of the smoke
a
larm, or if there are infants or family members with mobility limitations,
m
ake sure that someone is assigned to assist them in fire drill and in
t
he event of an emergency. It is recommended that you hold a fire drill
w
hile family members are sleeping in order to determine their response
t
o the sound of the smoke alarm while sleeping and to determine
w
hether they may need assistance in the event of an emergency.
S
moke Alarms cannot work without power. Battery operated units
c
annot work if the batteries are missing, disconnected or dead, if the
w
rong type of batteries are used, or if the batteries are not installed
c
orrectly. AC units cannot work if the AC power is cut off for any reason
(
open fuse or circuit breaker, failure along a power line or at a power
s
tation, electrical fire that burns the electrical wires, etc.). If you are
c
oncerned about the limitations of battery or AC power, install both
t
ypes of units.
Smoke Alarms cannot detect fires if the smoke does not reach
them. Smoke from fires in chimneys or walls, on roofs, or on the other
side of closed doors may not reach the sensing chamber and set
off the alarm. That is why one unit should be installed inside each
bedroom or sleeping area—especially if bedroom or sleeping area
doors are closed at night—and in the hallway between them.
Smoke Alarms may not detect fire on another floor or area of the
home. For example, a stand-alone unit on the second floor may not
detect smoke from a basement fire until the fire spreads. This may
not give you enough time to escape safely. That is why recommended
minimum protection is at least one unit in every sleeping area, and
every bedroom on every level of your home. Even with a unit on every
floor, stand-alone units may not provide as much protection as inter-
connected units, especially if the fire starts in a remote area. Some
safety experts recommend installing interconnected AC powered units
with battery back-up (see “About Smoke Alarms”) or professional
fire detection systems, so if one unit senses smoke, all units alarm.
Interconnected units may provide earlier warning than stand-alone
units since all units alarm when one detects smoke.
S
moke Alarms may not be heard. Though the alarm horn in this unit
m
eets or exceeds current standards, it may not be heard if: 1) the unit
i
s located outside a closed or partially closed door, 2) residents recently
c
onsumed alcohol or drugs, 3) the alarm is drowned out by noise from
s
tereo, TV, traffic, air conditioner or other appliances, 4) residents are
h
earing impaired or sound sleepers. Special purpose units, like those
w
ith visual and audible alarms, should be installed for hearing impaired
r
esidents.
Smoke Alarms may not have time to alarm before the fire itself
causes damage, injury, or death, since smoke from some fires may
not reach the unit immediately. Examples of this include persons
smoking in bed, children playing with matches, or fires caused by
violent explosions resulting from escaping gas.
Smoke Alarms are not foolproof. Like any electronic device, Smoke
Alarms are made of components that can wear out or fail at any time.
You must test the unit weekly to ensure your continued protection.
Smoke Alarms cannot prevent or extinguish fires. They are not a
substitute for property or life insurance.
Smoke Alarms have a limited life. The unit should be replaced
immediately if it is not operating properly. You should always replace a
Smoke Alarm after 10 years from date of purchase. Write the purchase
date on the space provided on back of unit.
First Alert
®
is a registered trademark of the First Alert Trust.
5
6
ABOUT SMOKE ALARMS
Battery (DC) operated Smoke Alarms: Provide protection even when
electricity fails, provided the batteries are fresh and correctly installed.
Units are easy to install, and do not require professional installation.
AC powered Smoke Alarms: Can be interconnected so if one unit
senses smoke, all units alarm. They do not operate if electricity fails.
AC with battery (DC) back-up: will operate if electricity fails, provided
the batteries are fresh and correctly installed. AC and AC/DC units
must be installed by a qualified electrician.
Smoke Alarms for Solar or Wind Energy users and battery backup
power systems: AC powered Smoke Alarms should only be operated
with true or pure sine wave inverters. Operating this Smoke Alarm with
most battery-powered UPS (uninterruptible power supply) products or
square wave or “quasi sine wave” inverters will damage the Alarm.
If you are not sure about your inverter or UPS type, please consult with
the manufacturer to verify.
Smoke Alarms for the hearing impaired: Special purpose Smoke
Alarms should be installed for the hearing impaired. They include a
visual alarm and an audible alarm horn, and meet the requirements of
the Americans With Disabilities Act. Can be interconnected so if one
unit senses smoke, all units alarm.
Smoke alarms are not to be used with detector guards unless the
combination has been evaluated and found suitable for that purpose.
All these Smoke Alarms are designed to provide early warning of fires if
located, installed and cared for as described in the user’s manual, and
if smoke reaches them. If you are unsure which type of Smoke Alarm
to install, refer to Chapter 2 of the National Fire Protection Association
(NFPA) Standard 72 (National Fire Alarm and Signaling Code) and
NFPA 101 (Life Safety Code). National Fire Protection Association,
One Batterymarch Park, Quincy, MA 02269-9101. Local building codes
may also require specific units in new construction or in different areas
of the home.
BEDROOM
B
EDROOM
HALL
LIVING ROOM KITCHEN
FINISHED BASEMENT
BEDROOM
BEDROOM
LIVING ROOM
D
INING ROOM
MULTI-STORY RESIDENCE
SINGLE-STORY RESIDENCE, APARTMENT,
MOBILE HOME
EXISTING HOMES
KITCHEN
REQUIRED TO
MEET NFPA
RECOMMENDATIONS
RECOMMENDED
FOR ADDITIONAL
PROTECTION
KEY:
SMOKE ALARMS WITH SILENCE
FEATURES RECOMMENDED FOR
ADDITIONAL PROTECTION
INTERCONNECTED
AC OR AC/DC
SMOKE ALARMS
BEDROOM
BEDROOM
HALL
LIVING ROOM KITCHEN
FINISHED BASEMENT
REQUIRED TO
MEET NFPA
RECOMMENDATIONS
RECOMMENDED
FOR ADDITIONAL
PROTECTION
BEDROOM
BEDROOM
LIVING ROOM
DINING ROOM
MULT I-STORY RESIDENCE
SINGLE-STORY RESIDENCE, APARTMENT,
MOBILE HOME
KEY:
NEW CONSTRUCTION
SMOKE ALARMS
WITH SILENCE
FEATURES
RECOMMENDED
FOR ADDITIONAL
PROTECTION
KITCHEN
IF THIS SMOKE ALARM SOUNDS
RESPONDING TO AN ALARM
During an alarm, you will hear a loud, repeating horn pattern:
3 beeps, pause, 3 beeps, pause. The Escape Light
®
will turn on.
LED flashes once every second.
If the unit alarms and you are not testing the unit, it is warning
you of a potentially dangerous situation that requires your
immediate attention. NEVER ignore any alarm. Ignoring the
alarm may result in injury or death.
Never remove the batteries from a battery operated Smoke Alarm
to stop an unwanted alarm (caused by cooking smoke, etc.).
Removing batteries disables the alarm so it cannot sense smoke,
and removes your protection. Instead open a window or fan the
smoke away from the unit. The alarm will reset automatically.
If the unit alarms get everyone out of the house immediately.
Printed in Mexico M08-0069-009 J1 02/12
+
OPTIONAL LOCKING FEATURES
The locking features are designed to discourage unauthorized removal of the battery or Alarm. It is not necessary to activate the locks in
single-family households where unauthorized battery or Alarm removal is not a concern.
These Smoke Alarms have two separate locking features: one to lock the battery compartment, and the other to lock the
Smoke Alarm to the mounting bracket. You can choose to use either feature independently, or use them both.
Tools you will need: • Needle-nose pliers or utility knife Standard Flathead screwdriver.
B
oth locking features use locking pins, which are molded into the mounting bracket. Using needle nose pliers or a utility knife,
r
emove one or both pins from the mounting bracket, depending on how many locking features you want to use.
T
o permanently remove either lock, insert a flathead screwdriver between the locking pin and the lock, and pry the pin out of the lock.
Locking Pin
TO LOCK THE BATTERY COMPARTMENT
Do not lock the battery compartment until you have installed the
battery and tested the unit.
1
. Push and hold Test/Silence button until the alarm sounds:
3
beeps, pause, 3 beeps, pause. The Escape Light
®
w
ill turn on.
L
ED flashes once every second.
I
f the unit does not alarm during testing, DO
N
OT lock the battery compartment! Install a
new battery and test again. If the Smoke Alarm
still does not alarm, replace it immediately.
2. Using needle-nose pliers or a
utility knife, detach one locking
pin from the mounting bracket.
3
. Push the locking pin through the
b
lack dot on the label on the
b
ack of the Smoke Alarm.
TO UNLOCK THE BATTERY COMPARTMENT
1
. Remove the Smoke Alarm from the mounting bracket. If the unit
i
s locked to the bracket, see the section “To Unlock the Mounting
B
racket.”
2. Insert a flathead screwdriver under the
head of the locking pin, and gently pry
it out of the battery compartment lock.
(If you plan to relock the battery
compartment, save the locking pin.)
3. To relock the battery compartment, close the battery door and
reinsert locking pin in lock.
4
. Reattach the Smoke Alarm to the mounting bracket.
When replacing the battery, always test the Smoke Alarm before
relocking the battery compartment.
TO UNLOCK THE MOUNTING BRACKET
1
. Insert a flathead screwdriver between the
m
ounting bracket pin and the mounting
b
racket.
2. Pry the Smoke Alarm
away from the
bracket by turning
both the screwdriver
and the Smoke Alarm
counterclockwise
(left) at the same
time.
TO LOCK THE MOUNTING BRACKET
1
. Using needle-nose pliers, detach one locking pin from mounting bracket.
2. Insert the locking pin into the lock located on the pivoting hinge of the
battery door.
3. When you attach the Smoke Alarm to the mounting bracket, the locking
pin’s head will fit into a notch on the bracket.
WHAT TO DO IN CASE OF FIRE
Don’t panic; stay calm. Follow your family escape plan.
Get out of the house as quickly as possible. Don’t stop to
get dressed or collect anything.
Feel doors with the back of your hand before opening them.
If a door is cool, open it slowly. Don’t open a hot door. Keep doors
and windows closed, unless you must escape through them.
Cover your nose and mouth with a cloth (preferably damp).
Take short, shallow breaths.
Meet at your planned meeting place outside your home,
and do a head count to make sure everybody got out safely.
Call the Fire Department as soon as possible from outside.
Give your address, then your name.
Never go back inside a burning building for any reason.
Contact your Fire Department for ideas on making your home safer.
Alarms have various limitations, See the section of this manual
titled "Limitations of Smoke Alarms".
REGULAR MAINTENANCE, Continued
Actual battery service life depends on the Smoke Alarm and the
environment in which it is installed. All the batteries specified above
are acceptable replacement batteries for this unit. Regardless of the
manufacturer’s suggested battery life, you MUST replace the battery
immediately once the unit starts “chirping” (the “low battery warning”).
USING THE SILENCE FEATURE
The Silence Feature can temporarily quiet an unwanted alarm for several
minutes. To use this feature, press the Test/Silence button on the cover.
The Escape Light
®
will turn off and and the LED will flash every 10 sec-
onds (for up to 10 minutes) to remind you the alarm has been silenced.
T
he Silence Feature does not disable the unit—it makes it temporar-
ily less sensitive to smoke. For your safety, if smoke around the unit
i
s dense enough to suggest a potentially dangerous situation, it
will stay in alarm, or may re-alarm quickly. If you do not know the
s
ource of the smoke, do not assume it is an unwanted alarm. Not
responding to an alarm can result in property loss, injury or death.
Alarm Base
1. Battery Compartment
2. Test/Silence button
3. Escape Light
®
This unit is designed to be mounted on
the ceiling, or on the wall if necessary.
DO NOT attach this Alarm to an electrical junction box.
Attachment to an electrical box may impair the Alarm’s operation.
Attach directly to wallboard or flat wall or ceiling surface.
4
Page view 0
1 2

Summary of Contents

Page 1 - STANDARD

IMPORTANT! PLEASE READ CAREFULLY AND SAVE.This user’s manual contains important information about your Smoke Alarm’s operation.If you are installing

Page 2 - CASAS YA CONSTRUIDAS

MANUAL DEL USUARIOM08-0069-009 J1 02/12 Impreso en MéxicoCONTENIDOSugerencias de seguridad en caso de incendio . . . . . . . . . . . . . . . . . .

Comments to this Manuals

No comments