FIRE SAFETY TIPS
Follow safety rules and pr
event hazardous situations: 1) Use smoking
materials pr
operly. Never smoke in bed. 2) Keep matches or lighters
away from children; 3) Store flammable materials in proper containers;
4) Keep electrical appliances in good condition and don’
t overload
electrical circuits; 5) Keep stoves, barbecue grills, fireplaces and
chimneys grease- and debris-free; 6) Never leave anything cooking on
the stove unattended; 7) Keep portable heaters and open flames, like
candles, away from flammable materials;8) Don’t let rubbish accumulate.
Keep alarms clean, and test them weekly. Replace alarms immediately
if they ar
e not working properly. Smoke Alarms that do not work cannot
alert you to a fir
e. Keep at least one working fire extinguisher on every
floor, and an additional one in the kitchen. Have fire escape ladders or
other r
eliable means of escape from an upper floor in case stairs are
blocked.
BASIC SAFETY INFORMA
TION
• Dangers, Warnings, and Cautions alert you to important
operating instr
uctions or to potentially hazardous situations.
Pay special attention to these items.
This Smoke/CO Alarm is approved for use in single-family
r
esidences.
This combination Smoke/Carbon Monoxide Alarm has two
separate alarms. The CO Alarm is not designed to detect fire
or any other gas. It will only indicate the pr
esence of carbon
monoxide gas at the sensor. Carbon monoxide gas may be
present in other areas. The Smoke Alarm will only indicate the
pr
esence of smoke that reaches the sensor. The Smoke Alarm
is not designed to sense gas, heat or flames.
• This Smoke/CO Alarm cannot operate without working
batteries. Removing the batteries for any reason, or failing to
replace the batteries at the end of their service life, removes
your protection.
• NEVER ignore any alarm. See “If Your Smoke/CO Alarm
Sounds” for mor
e information on how to respond to an alarm.
Failur
e to respond can result in injury or death.
The Silence Features are for your convenience only and will
not correct a problem. See "Using the Silence Features" for
details. Always check your home for a potential problem after
any alarm. Failure to do so can result in injury or death.
• Test this Smoke/CO Alarm once a week. If the Alarm ever fails
to test correctly, have it replaced immediately! If the Alarm is
not working properly, it cannot alert you to a problem.
• This product is intended for use in ordinary indoor locations
of family living units. It is not designed to measure CO levels
in compliance with Occupational Safety and Health
Administration (OSHA) commercial or industrial standards.
Individuals with medical conditions that may make them more
sensitive to carbon monoxide may consider using warning
devices which provide audible and visual signals for carbon
monoxide concentrations under 30 ppm. For additional
information on carbon monoxide and your medical condition
contact your physician.
2
STEP BY STEP GUIDE TO PROGRAMMING
THIS ALARM
FOR FIRST TIME AND WHEN CHANGING BATTERIES
Action:
1. Insert batteries (2, AA batteries).
Alar
m W
ill Say:
“Welcome, First Alert Smoke and
Carbon Monoxide Alarm.”
“No location programmed” if first
time
or “[Location, example:
“Basement”] location pr
ogrammed”
when changing batteries.
“To select location, press and hold
test button now
.”
2.
Pr
ess & Hold Test Button if
you would like to program the
location or change the location
of the Alarm. Release button
after Alarm responds.
“T
o save location, pr
ess and hold
test button after location is heard.”
Alarm will speak list of locations
(see below).
3. After you hear the location of
where you are placing the Alarm,
Press & Hold the Test Button.
“[Location, example: “Basement”]
location saved.”
If no location is chosen:
“No location saved.”
Your Alarm has now been programmed for the location of your choice.
Available locations:
Basement Kitchen Child’s Bedroom
Living Room
Dining Room
Master Bedr
oom
Family Room No Location Guest Bedroom
Office Hallway Utility Room
NOTE: Steps 1 thr
ough 3 need to be completed within two minutes.
If mor
e than two minutes pass, the Green power LED will stop
blinking. Simply open the battery drawer of the second Alarm and
r
epeat steps 1 through 3.
1.
Insert the batteries into the
battery drawer of the next
Alarm. DO NOT CLOSE THE
DRA
WER.
2. Press and hold the test
button and then close the
battery drawer.
3.
Once you hear the unit chirp,
r
elease the test button.
The Green power LED will start to blink indicating the ONELINK
®
Alarm is waiting for pr
ogram data from one of the other setup
ONELINK
®
Alarms.
4. Press and hold the test button on the first Alarm, until the second
Alarm
chirps and its Gr
een power LED stops blinking. Then release
the test button.
5.
If you have purchased the hardwired battery back-up ONELINK
®
Alarm, you can now connect the har
dwired Alarm by installing the
three-wire connector on the ceiling to the Alarm.
6.
Repeat steps 1-5 for additional ONELINK
®
Alarms.
You have now successfully linked your new ONELINK
®
Alarms. To
add additional Alarms at a later time, follow steps 1 through 5.
ADDING AND LINKING ADDITIONAL ONELINK
®
ALARMS
WHAT YOU WILL SEE AND HEAR WITH THIS ALARM
Under Normal Operations
Voice: Silent Power/Smoke LED: Flashes Green
once a minute
Horn: Silent CO LED: Off
When Y
ou Test the Alarm
Voice: “Testing.” Horn: 3 beeps, pause, 3 beeps; Voice: “Warning,
evacuate smoke in [Location, example: “Basement”].
Evacuate.”
Smoke LED: Flashes Red in sync with the horn pattern
Horn: 4 fast beeps, pause, 4 fast beeps;
Voice: “Warning, evacuate carbon monoxide in [Location, example:
“Basement”]. Evacuate.” Pause. “Highest carbon monoxide
level was [CO level example: _0_ ppm]”.
CO LED: Flashes Red in sync with the horn pattern
If Battery Becomes Low or is Missing
Voice: “Replace battery in [Location, example “Kitchen”].” Repeated
every 5 hours
Horn: chirps once a minute
Power/Smoke LED: Flashes Green On for 2 seconds/Off for
2 seconds. Low Battery Latch is now engaged.
CO LED: Off
If Alarm is Not Operating Properly (MALFUNCTION SIGNAL)
V
oice:
“Detector err
or in [Location, example “Kitchen”], please see
manual” (refer to Troubleshooting Guide).
Repeated every 5 hours.
Horn: Three rapid chirps every minute
Power/Smoke LED: Flashes approximately once a minute
CO LED: Off
Alar
m Levels of CO are Detected
Voice: “Warning, evacuate carbon monoxide in [Location, example:
“Kitchen”]. Evacuate.” “
____ ppm.”
Hor
n:
4 beeps, pause, 4 beeps, voice*
Power/Smoke LED: Of
f
CO LED: During Alarm: Flashes Red in sync with the horn pattern.
After Alarm: Flashes Red On for 2 seconds/Off for 2
seconds. CO Alarm Latch is now engaged.
*NOTE: If unit goes into CO alarm, the r
egular 4 beeps-brief pause
cycle will repeat for four minutes. After four minutes, the pause will
increase to one minute.
Smoke is Detected
Voice: “Warning, evacuate smoke in [Location, example: “Kitchen”].
Evacuate.”
Hor
n:
3 beeps, pause, 3 beeps, voice
Power/Smoke LED: During Alarm: Flashes Red in sync with the
hor
n pattern. After Alarm: Flashes Red On for 2 seconds/
Off for 2 seconds. Smoke Alarm Latch is now engaged.
CO LED: Off
Smoke Alarm is Silenced
Voice: Silent
Hor
n:
Of
f
Power/Smoke LED: Flashes Red
CO LED: Off
CO Alarm is Silenced
Voice: Silent
Hor
n:
Of
f
Power/Smoke LED: Off
CO LED: Flashes Red
Page view 1
1 2 3 4 5 6 7 8 9 10