First Alert Atom Smoke Alarm User Manual Page 2

  • Download
  • Add to my manuals
  • Print
  • Page
    / 2
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 1
LIMITED WARRANTY
BRK Brands, Inc., (“BRK”) the maker of First Alert
®
brand products
warrants that for a period of ten years from the date of purchase, this
product will be free from defects in material and workmanship. BRK, at
its option, will repair or replace this product or any component of the
product found to be defective during the warranty period. Replacement
will be made with a new or remanufactured product or component. If
the product is no longer available, replacement may be made with a
similar product of equal or greater value. This is your exclusive warranty.
This warranty is valid for the original retail purchaser from the date of
initial retail purchase and is not transferable. Keep the original sales
receipt. Proof of purchase is required to obtain warranty performance.
BRK dealers, service centers, or retail stores selling BRK products do
not have the right to alter, modify or any way change the terms and
conditions of this warranty.
This warranty does not cover normal wear of parts or damage resulting
from any of the following: negligent use or misuse of the product, use on
improper voltage or current, use contrary to the operating instructions,
disassembly, repair or alteration by anyone other than BRK or an
authorized service center. Further, the warranty does not cover Acts of
God, such as fire, flood, hurricanes and tornadoes or any batteries that
are included with this unit.
BRK shall not be liable for any incidental or consequential damages
caused by the breach of any express or implied warranty. Except to
the extent prohibited by applicable law, any implied warranty of
merchantability or fitness for a particular purpose is limited in duration
to the duration of the above warranty. Some states, provinces or
jurisdictions do not allow the exclusion or limitation of incidental or
consequential damages or limitations on how long an implied warranty
lasts, so the above limitations or exclusion may not apply to you. This
warranty gives you specific legal rights, and you may also have other
rights that vary from state to state or province to province.
How to Obtain Warranty Service
Service: If service is required, do not return the product to your retail-
er. In order to obtain warranty service, contact the Consumer Affairs
Division at 1-800-323-9005, 7:30 AM - 5:00 PM Central Standard Time,
Monday through Friday. To assist us in serving you, please have the
model number and date of purchase available when calling.
For Warranty Service return to:
BRK Brands, Inc., 25 Spur Drive, El Paso, TX 79906
Battery: BRK Brands, Inc. make no warranty, express or implied, written
or oral, including that of merchantability or fitness for any particular
purpose with respect to battery.
LOCATIONS TO AVOID FOR SMOKE ALARMS, Continued
In very damp, humid or steamy areas, or directly near bathrooms with
showers. Keep units at least 10 feet (3 meters) away from showers, sau-
nas, dishwashers, etc.
Where the temperatures are regularly below 40˚ F (4.4˚ C) or above 100˚ F
(37.8˚ C), including unheated buildings, outdoor rooms, porches, or unfin-
ished attics or basements.
In very dusty, dirty, or greasy areas. Do not install a Smoke Alarm directly
over the stove or range. Keep laundry room Smoke Alarms free of dust or
lint.
Near fresh air vents, ceiling fans, or in very drafty areas. Drafts can
blow smoke away from the unit, preventing it from reaching the sensing
chamber.
In insect infested areas. Insects can clog openings to the sensing
chamber and cause unwanted alarms.
Less than 12 inches (305mm) away from fluorescent lights. Electrical
noise” can interfere with the sensor.
In dead air” spaces. Dead air” spaces may prevent smoke from
reaching the Smoke Alarm.
Avoiding Dead Air Spaces
Dead air” spaces may prevent smoke from reaching the Smoke Alarm.
To avoid dead air spaces, follow the installation recommendations below.
On ceilings, install Smoke Alarms as close to the center of the ceiling as
possible. If this is not possible, install the Smoke Alarm at least 4 inches
(102 mm) from the wall or corner.
For wall mounting (if allowed by building codes), the top edge of Smoke
Alarms should be placed between 4 and 12 inches (102 and 305 mm) from
the wall/ceiling line, below typical “dead air” spaces.
On a peaked, gabled, or cathedral ceiling, install the first Smoke Alarm
within 3 feet (0.9 meters) of the peak of the ceiling, measured horizontally.
Additional Smoke Alarms may be required depending on the length, angle,
etc. of the ceilings slope. Refer to NFPA 72 for details on requirements for
sloped or peaked ceilings.
ABOUT SMOKE ALARMS
Battery (DC) operated Smoke Alarms: Provide protection even when
electricity fails, provided the batteries are fresh and correctly installed.
Units are easy to install, and do not require professional installation. However,
they do not provide interconnected functionality.
AC powered Smoke Alarms: Can be interconnected so if one unit senses
smoke, all units alarm. They do not operate if electricity fails.
AC with battery (DC) back-up: will operate if electricity fails, provided the
batteries are fresh and correctly installed. AC and AC/DC units must be
installed by a qualified electrician.
Wireless Interconnected Alarms: Offer the same interconnected
functionality as with hardwired alarms, without wires. Units are easy to install
and do not require professional installation. They provide protection even
when electricity fails, provided the batteries are fresh and correctly installed.
Smoke Alarms for Solar or Wind Energy users and battery backup
power systems: AC powered Smoke Alarms should only be operated with true
or pure sine wave inverters. Operating this Smoke Alarm with most
battery-powered UPS (uninterruptible power supply) products or square wave or
quasi sine wave inverters will damage the Alarm. If you are not sure about
your inverter or UPS type, please consult with the manufacturer to verify.
Smoke Alarms for the hearing impaired: Special purpose Smoke Alarms
should be installed for the hearing impaired. They include a visual alarm and
an audible alarm horn, and meet the requirements of the Americans With
Disabilities Act. These units can be interconnected so if one unit senses
smoke, all units alarm.
Smoke alarms are not to be used with detector guards unless the
combination has been evaluated and found suitable for that purpose.
All these Smoke Alarms are designed to provide early warning of fires
if located, installed and cared for as described in the user
s manual, and if
smoke reaches the Alarm. If you are unsure which type of unit to install, refer
to NFPA (National Fire Protection Association) 72 (National Fire Alarm and
Signaling Code) and NFPA 101 (Life Safety Code). National Fire Protection
Association, One Batterymarch Park, Quincy, MA 02269-9101. Local building
codes may also require specific units in new construction or in different areas
of the home.
RECOMMENDED LOCATIONS FOR
SMOKE ALARMS
Installing Smoke Alarms in Single-Family Residences
The National Fire Protection Association (NFPA), recommends one
Smoke Alarm on every floor, in every sleeping area, and in every bed-
room. In new construction, the Smoke Alarms must be AC powered and
interconnected. See Agency Placement Recommendations for details.
For additional coverage, it is recommended that you install a Smoke
Alarm in all rooms, halls, storage areas, finished attics, and basements,
where temperatures normally remain between 40˚ F (4.4˚ C) and 100˚ F
(37.8˚ C). Make sure no door or other obstruction could keep smoke from
reaching the Smoke Alarms.
More specifically, install Smoke Alarms:
On every level of your home, including finished attics and basements.
Inside every bedroom, especially if people sleep with doors closed.
In the hall near every sleeping area. If your home has multiple sleep-
ing areas, install a unit in each. If a hall is over 40 feet (12 meters)
long, install an alarm at each end.
At the top of the first-to-second floor stairway, and at bottom of
basement stairway.
Specific requirements for Smoke Alarm installation vary from state to
state and from region to region. Check with your local Fire Department
for current requirements in your area. It is recommended AC or AC/
DC units be interconnected for added protection.
LOCATIONS TO AVOID FOR SMOKE ALARMS
For best performance, it is recommended you AVOID installing Smoke
Alarms in these areas:
Where combustion particles are produced. Combustion particles form
when something burns. Areas to avoid include poorly ventilated kitchens,
garages, and furnace rooms. Keep units at least 20 feet (6 meters) from
the sources of combustion particles (stove, furnace, water heater, space
heater) if possible. In areas where a 20-foot (6-meter) distance is not pos-
sible – in modular, mobile, or smaller homes, for example – it is
recommended the Smoke Alarm be placed as far from these fuel-burning
sources as possible. The placement recommendations are intended to
keep these Alarms at a reasonable distance from a fuel-burning source,
and thus reduce “unwanted” alarms. Unwanted alarms can occur if a
Smoke Alarm is placed directly next to a fuel-burning source. Ventilate
these areas as much as possible.
In air streams near kitchens. Air currents can draw cooking smoke into
the sensing chamber of a Smoke Alarm near the kitchen.
Continued...
California State Fire Marshal (CSFM)
Early warning detection is best achieved by the installation of fire detection
equipment in all rooms and areas of the household as follows: A Smoke
Alarm installed in each separate sleeping area (in the vicinity, but outside
bedrooms), and Heat or Smoke Alarms in the living rooms, dining rooms, bed-
rooms, kitchens, hallways, finished attics, furnace rooms, closets, utility and
storage rooms, basements, and attached garages.
AGENCY PLACEMENT RECOMMENDATIONS
NFPA 72 Chapter 29
For your information, the National Fire Alarm and Signaling Code,
NFPA 72, reads as follows:”
29.5.1* Required Detection.
29.5.1.1* Where required by other governing laws, codes, or standards
for a specific type of occupancy, approved single and multiple-station
smoke alarms shall be installed as follows:
(1)*In all sleeping rooms and guest rooms
(2)* Outside of each separate dwelling unit sleeping area, within 21 ft (6.4
m) of any door to a sleeping room, with the distance measured along
a path of travel
(3) On every level of a dwelling unit, including basements
(4) On every level of a residential board and care occupancy (small
facility), including basements and excluding crawl spaces and
unfinished attics
(5)*In the living area(s) of a guest suite
(6) In the living area(s) of a residential board and care occupancy
(small facility)
(Reprinted with permission from NFPA 72
®
, National Fire Alarm and
Signaling Code Copyright © 2010 National Fire Protection Association,
Quincy, MA 02269. This reprinted material is not the complete and
official position of the National Fire Protection Association, on the
referenced subject which is represented only by the standard in its
entirety), (National Fire Alarm and Signaling Code
®
and NFPA 72
®
are
registered trademarks of the National Fire Protection Association, Inc.,
Quincy, MA 02269).
3
SPECIAL COMPLIANCE CONSIDERATIONS
This Smoke Alarm is suitable for use in apartments, condominiums, town-
houses, hospitals, day care facilities, health care facilities, boarding houses,
group homes and dormitories provided a primary fire detection system
already exists to meet fire detection requirements in common areas like lob-
bies, hallways, or porches. Using this Smoke Alarm in common areas may
not provide sufficient warning to all residents or meet local fire protection
ordinances/regulations.
This Smoke Alarm alone is not a suitable substitute for complete fire detection
systems in places housing many people—like apartment buildings,
condominiums, hotels, motels, dormitories, hospitals, health care facilities,
nursing homes, day care facilities, or group homes of any kind. It is not a suit-
able substitute for complete fire detection systems in warehouses,
industrial facilities, commercial buildings, and special-purpose non-residential
buildings which require special fire detection and alarm systems. Depending
on the building codes in your area, this Smoke Alarm may be used to
provide additional protection in these facilities.
In new construction, most building codes require the use of AC or AC/DC
powered Smoke Alarms only. In existing construction, AC, AC/DC, or DC pow-
ered Smoke Alarms can be used as specified by local building codes. Refer
to NFPA 72 (National Fire Alarm and Signaling Code) and NFPA 101 (Life Safety
Code), local building codes, or consult your Fire Department for detailed fire
protection requirements in buildings not defined as “households.
HUD MAP Program
Certain HUD battery powered Smoke Alarm applications, especially those
that fall under HUD 223(f) MAP (Multi-family Accelerated Processing), may
require a 10 Year sealed tamper resistant battery. This alarm does not meet
that requirement. Substitute First Alert SA340B.
LIMITATIONS OF SMOKE ALARMS
Smoke Alarms have played a key role in reducing deaths resulting from home
fires worldwide. However, like any warning device, Smoke Alarms can only
work if they are properly located, installed, and maintained, and if smoke
reaches them. They are not foolproof.
Smoke alarms may not waken all individuals. Practice the escape plan
at least twice a year, making sure that everyone is involved – from kids to
grandparents. Allow children to master fire escape planning and practice
before holding a fire drill at night when they are sleeping. If children or others
do not readily waken to the sound of the smoke alarm, or if there are infants
or family members with mobility limitations, make sure that someone is
assigned to assist them in fire drill and in the event of an emergency. It is rec-
ommended that you hold a fire drill while family members are sleeping
in order to determine their response to the sound of the smoke alarm while
sleeping and to determine whether they may need assistance in the event
of an emergency.
Smoke Alarms cannot work without power. Battery operated units cannot
work if the batteries are missing, disconnected or dead, if the wrong type
of batteries are used, or if the batteries are not installed correctly. AC units
cannot work if the AC power is cut off for any reason (open fuse or circuit
breaker, failure along a power line or at a power station, electrical fire that
burns the electrical wires, etc.). If you are concerned about the limitations
of battery or AC power, install both types of units.
Smoke Alarms cannot detect fires if the smoke does not reach them.
Smoke from fires in chimneys or walls, on roofs, or on the other side of closed
doors may not reach the sensing chamber and set off the alarm. That is why
one unit should be installed inside each bedroom or sleeping area—especial-
ly if bedroom or sleeping area doors are closed at night—and in the hallway
between them.
Smoke Alarms may not detect fire on another floor or area of the home.
For example, a stand-alone unit on the second floor may not detect smoke
from a basement fire until the fire spreads. This may not give you enough time
to escape safely. That is why recommended minimum protection is
at least one unit in every sleeping area, and every bedroom on every level
of your home. Even with a unit on every floor, stand-alone units may not
provide as much protection as interconnected units, especially if the fire starts
in a remote area. Some safety experts recommend installing interconnected
AC powered units with battery back-up (see About Smoke Alarms”) or pro-
fessional fire detection systems, so if one unit senses smoke, all units alarm.
Interconnected units may provide earlier warning than stand-alone units since
all units alarm when one detects smoke.
Smoke Alarms may not be heard. Though the alarm horn in this unit meets
or exceeds current standards, it may not be heard if: 1) the unit is located
outside a closed or partially closed door, 2) residents recently consumed
alcohol or drugs, 3) the alarm is drowned out by noise from stereo, TV, traffic,
air conditioner or other appliances, 4) residents are hearing impaired or sound
sleepers. Special purpose units, like those with visual and audible alarms,
should be installed for hearing impaired residents.
Smoke Alarms may not have time to alarm before the fire itself causes
damage,injury,ordeath,sincesmokefromsomefiresmaynotreach
the unit immediately. Examples of this include persons smoking in bed,
children playing with matches, or fires caused by violent explosions
resulting from escaping gas.
Smoke Alarms are not foolproof. Like any electronic device, Smoke Alarms
are made of components that can wear out or fail at any time. You must test
the unit weekly to ensure your continued protection. Smoke Alarms cannot
prevent or extinguish fires. They are not a substitute for property or life
insurance.
Smoke Alarms have a limited life. The unit should be replaced immediately
if it is not operating properly. You should always replace a Smoke Alarm
after 10 years from date of purchase. Write the purchase date on the space
provided on back of unit.
First Alert
®
is a registered trademark of the First Alert Trust.
Printed in China M08-0410-010 04/14
IF YOU SUSPECT A PROBLEM, Continued
• Ifthealarmsoundswhennosmokeisvisible,trycleaningor
relocating the Smoke Alarm. The cover may be dirty.
• Ifthealarmdoesnotsoundduringtesting,tryinstallinganew
battery, and make sure it is snapped in securely.
Do not try fixing the alarm yourself – this will void your warranty!
If the Smoke Alarm is still not operating properly, and it is still under
warranty, please see “How to Obtain Warranty Service” in the Limited
Warranty.
4